Rolls-Royce Archives
         « Prev  Box Series  Next »        

From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).
Specifying fuse capacities and testing procedures for dynamo circuits.

Identifier  ExFiles\Box 61\2\  scan0293
Date  6th August 1919
  
-2-

Contd.

(d) Fuse in control circuit.
(e) Fuse in negative circuit
(f) Fuses in both circuits.

Initially, fuses of 15 ampere capacity should be tried, later on, when we obtain them, fuses of 20 ampere capacity should be tried if necessary. Each case should be investigated with the dynamo in both a hot and cold condition. For passing the short circuited current an independent switch should be joined as a shunt across the cutout to simulate the condition of the cutout sticking in the "on" position.

Ck.{Mr Clark}

R.R.E. 255 A (100 T.) (S.F.) 846. 6-8-19 (8-19) G.{Mr Griffiths - Chief Accountant / Mr Gnapp} 2460.
  
  