Rolls-Royce Archives
         « Prev  Box Series  Next »        

Calculations for a petrol venturi meter, determining flow rates.


Identifier  ExFiles\Box 37\2\  scan 143
Date  2nd July 1919 guessed
  
X. 3180

Head galls/min √Head Const-

4.05 .375 2.01 .1865
4.91 .410 2.22 .1846.
5.87 .457 2.42 .1890.
6.94 .487 2.63 .1850
7.96 .533 2.82 .1890.

5 / 9341
.1867.

.187 √H. {Arthur M. Hanbury - Head Complaints}

X.3180. Petrol Venturi
Meter

Av of last two
Galls/min = .1865 √H


Pints/hour = 89.5 √H. {Arthur M. Hanbury - Head Complaints}


40% addition found necessary by exps in
test house No.12. makes
Galls/min = .194 √H
Pints/hour = 93.1 √H
  
  