Investigation report on a faulty coil (ref X.4273), identifying a short circuit in the secondary winding.
| Identifier | ExFiles\Box 47\4\ Scan066 | |
| Date | 2nd November 1923 | |
| X4118 To EY. from EFC. {E. Fowler Clarke - Electrical Engineer} EFC {E. Fowler Clarke - Electrical Engineer} 2/T2.11.23. X.4273 - RE FAULTY COIL - 62-H-6. HARRISON. We have investigated this coil. Put through the routine production test, this coil appeared O.K. with the exception that the secondary milliamperes were high. Also that the open circuit test was not continued for more than two minutes out of five, because the coil was heard to be sparking across inside. On further test under running conditions the coil for some time appeared to be O.K., but after running for about 10 minutes, the sparking failed altogether, after which failure the secondary milliamperes had increased still further. It appears clear from this that the failure is in the secondary, and that some portion of this winding has become short circuited by it. Our tests do not indicate that anything is wrong with the primary winding. We are returning the coil to you herewith. We shall be pleased to make a special investigation of this breakdown by unwinding the coil, if you so desire. EFC. {E. Fowler Clarke - Electrical Engineer} | ||
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).