Instructions for checking the capacity and charge retention of a condenser.

Identifier  ExFiles\Box 52\3\  Scan117
Date  25th August 1928 guessed
  
(10) The capacity of the condenser should be checked at a temperature of 45°C, and should fall within the limits .41 to .52 mf. It should also be ascertained that at this temperature, the condenser is still capable of holding a static charge for a time long enough to observe this on causing the condenser to discharge.

EFC. {E. Fowler Clarke - Electrical Engineer}
  
  