List of S.U. petrol pumps removed from Bentley chassis during June 1939, detailing failures and owner complaints.

Identifier  ExFiles\Box 162\1\  img012
Date  10th July 1939
  
To. By from Pk/KC/FED.
c.c to Rm{William Robotham - Chief Engineer}/JSD
Rm{William Robotham - Chief Engineer}/GWH{George W. Hancock - Head Chateauroux} - File

W/Kingsbury 10th July 1939.

We give below a complete list of S.U. petrolpumps
removed from Bentley chassis during the month of June 1939, and
where possible the Owner's complaint and the Pump's mileage.

Date Chassis Mlg. Piece No Reason rejected
2:6:39 B. 22 C.R. 25695 D.B. 447 Nearside weak. (Modified unit fitted
2:6:39 B. 77 D.K. 4040 G.S.S.C. No:2.85.Intermittent sticking.
5:6:39 B.110 H.K. 18733 G.S.S.C. No:1168.Leaking offside vent.
5:6:39 B.143 H.M. 27082 G.5. Leaking nearside vent.
5:6:39 B.182 E.F. --- G.S.S.C. No:17.Defective (owner's complaint)
6:6:39 B.127 H.M. 10122 G.S.S.C. No:2078.Noisy and fails.
6:6:39 B. 28 A.H. 5498 G.S.S.C. No:Occasional failure.
7:6:39 B. 62 F.B. 33298 D.B. 447 Failed on road.(repaired outside)
7:6:39 B.133 H.M. 47713 D.B. 447 Offside unit not working.
8:6:39 B.138 F.B. 44907 D.B 447 leaking both vents.
8:6:39 B. 22 B.N. 5549 G.S.S.C. No:276.Continually failing.
8:6:39 B.108 H.K. 11321 G.5. Nearside unit very weak.
8:6:39 B.100 G.A.F. --- G.S.S.C. No:229. Failure.
8:6:39 B.180 D.G. 30815 D.B. 447 Continually sticking.
9:6:39 B. 94 J.D. 8344 G.S.S.C. No:2035.Continually failing.
9:6:39 B. 58 C.R. --- G.S.S.C. No:1956.Defective.Owner's complaint.
12:6:39 B. 14 K.T. 15331 G.S.S.C. No:1172.N/side unit leaking at vent
12:6:39 B. 82 M.K. 13154 G.S.S.C. No:2182.Nearside unit fails.
13:6:39 B.122 C.R. 12079 G.S.S.C. No:398.Offside unit not working.
14:6:39 B.157 G.P. 14801 G.S.S.C. No:389.leaking both vents.
14:6:39 B. 71 M.E. 9672 G.S.S.C. No:2159.leaking offside vent.
15:6:39 B. 50 G.A. 15172 G.5. Nearside unit not working.
15:6:39 B.170 G.A. 9108 G.S.S.C. No:454.Nearside unit faulty.
16:6:39 B.192 H.K. 17108 G.S.S.C. No:1993.Offside unit not working.
16:6:39 B. 75 G.P. 23448 G.5. Offside unit not working.
19:6:39 B.165 A.E. 64613 D.B. 447 O/side not working and leaking.
20:6:39 B. 12 J.D. 28143 G.5. Leaking both vents
20:6:39 B. 75 B.N. 46092 G.5. Offside unit not working.
23:6:39 B. 5 H.M. 18738 G.5. leaking both vents.
23:6:39 B.108 J.D. 9985 G.5. leaking both vents.
23:6:39 B. 3 L.E. 9815 G.S.S.C. No:1991.leaking nearside vent.
23:6:39 B.201 H.M. 20023 G.S.S.C. No:795.Faulty and noisy.
23:6:39 B. 19 F.C. 3978 G.S.S.C. No:1901.Failed on road and noisy.
24:6:39 B. 46 C.R. --- G.S.S.C. No:686.Total failure.
27:6:39 B. 15 A.E. --- G.S.S.C. No:465. Failed on road
27:6:39 B.165 A.T. 5545 G.S.S.C. No:580.Offside unit noisy and leaking
27:6:39 B. 83 H.M. 28901 G.5. leaking offside vent.
28:6:39 B. 93 J.Y. 9683 G.5. leaking nearside vent.
28:6:39 B.170 G.A. 9852 G.S.S.C. No:79.Offside unit failed on road.
29:6:39 B. 24 C.R. 47810 D.B. 447 Continually failing.
29:6:39 B.118 G.A. 33865 D.B. 447 Continually failing.
29:6:39 B.100 B.N. 12711 G.5. leaking and intermittant failure.
29:6:39 B. 7 F.C. 16823 G.S.S.C. Nearside unit faulty.
29:6:39 B.163 D.K. 5000 G.S.S.C. No:2390.Failure.
29:6:39 B.127 D.K. 19413 G.S.S.C. No:197.Nearside continually failing.
29:6:39 B. 72 J.Y. 23747 G.S.S.C. No:904.Complete failure.
30:6:39 B.190 C.R. 39166 D.B. 447 Modified type fitted.
30:6:39 B. 49 C.W. 19939 D.B. 447 Offside unit very noisy.
  
  