From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).
Test report on the capacity of standard and production condensers, noting one is outside limits.
Identifier | ExFiles\Box 52\3\ Scan096 | |
Date | 13th June 1923 | |
X4430 To Wor {Arthur Wormald - General Works Manager} /Mr. Brock. EFC {E. Fowler Clarke - Electrical Engineer} 3/T13.6.23. RE PRODUCTION & STANDARD CONDENSERS HANDED TO US FOR TEST. We find the exact capacity of your standard condenser at 18°C, to be .243 mf., with a possible error each way not exceeding ½%. As regards the six production condensers, we find the capacities at 18°C to be as follows :- No.478. .284 mf. 515. .273 " 521. .317 " 523. .284 " 524. .290 " 530. .246 " from which you will note that No.530 is definitely outside the production limits. EFC. {E. Fowler Clarke - Electrical Engineer} EFC. {E. Fowler Clarke - Electrical Engineer} | ||