Test report on the lag in action of an actuator box and switch, detailing electrical resistance, current, and load measurements.

Identifier  ExFiles\Box 34\3\  Scan055
Date  15th December 1919
  
R.R. 235 a (100 T) N.Y. 575. 16.4.19(G) 3254

X.2641.

Dec.15th 1919.

X.3428 - LAG IN ACTION OF ACTUATOR BOX. X.3748.
X.2641.

(a) Standard Actuator, Main Switch & Push Button Switch.

Resistance of Main Switch coil cold = 9.0Ohms.

Current to just cause full contact = .75 amps.

Clearances conformed with the standard given.


Resistance of Actuator coils = 4.27 ohms.

Least current for "click on" = 1.45 amps.

Motion at end of arm = .200"

Force applied to end of arm to cause "click on" = 2 lb. 8 ozs.


Actuator box and main switch were connected
in parallel across a 12 volt battery.

Current through actuator coils = 2.63 amp.turns = 3200

" " main switch coil = 1.20,
Amp. turns = 1100

Maximum load lifted by actuator arm = 42 ozs.
(coil cold).

If push button contact made slowly, there is
noticeable lag of actuator, when load on arm is 75% of
maximum which actuator is capable of lifting. When load on
arm is 92% of maximum, there is no pull on, if only the
carbons of push button make contact.

Contd.
  
  