Test results and specifications for an actuator box with two coils.

Identifier  ExFiles\Box 34\3\  Scan056
Date  16th June 1939
  
-2- contd.

(b) Actuator Box with 2 coils in series each of 400# turns of 20 S.W.G. D.S.C. copper.

Resistance cold = 1.65 ohms.

Current to pull on light = 1.65 amps.

Load which, when applied at end of arm, just overcomes friction of motion work = 1 lb.10 ozs.

Current when connected to 12 volt battery (coils cold) = 6.25 amps.

" Amp turns = 800 x 6.25 = 5000

Maximum load lifted at end of arm (coils cold) = 93 ozs. (5 lbs.13 ozs)

Connected in parallel with standard main switch and across terminals of 12 volt battery :-

Current through main switch = 1.10, Amp.turns = 1020
" " actuator = 6.20, " " = 4960

Total. 7.30 amps.

If push button switch closed slowly, and the load on arm is 75 - 80% of maximum lifted, there is a noticeable lag of the actuator box in pulling on.

If the load on arm is 95% of maximum, there is no pull on, if only the carbons of push button close.

Contd.
  
  