Calculating the stress and friction for bolts with forced-on collars.

Identifier  ExFiles\Box 74\1\  scan0174
Date  16th October 1923
  
X.1334

To BY.{R.W. Bailey - Chief Engineer} from E.{Mr Elliott - Chief Engineer}
c. to HS.{Lord Ernest Hives - Chair}

E4/M16.10.23.

RE. BOLTS WITH FORCED ON COLLARS. X.1334.

In reply to your BY1/P2.10.23., it is assumed to begin with that a short length of the bolt stem is left proud for the reception of the collar so that this latter can be forced into its position with great pressure, leaving the metal of the collar stressed up to say 20 tons per sq.in.

The next point is the co-efficient of friction.
Mr. Royce is of the opinion that this would be 100% under the conditions given.

The sectional of the collar on one side is .062 X .6 = .0372 per sq.in.

Tension in the collar is 20 X .0372 = 744 tons.

Multiply by 2 for total load on bolt stem,
744 X 2 = 4.68 tons.

The end pull on the bolt to move this collar would be 4.68 tons.

Section area at bottom of bolt thread = .0767.

Stress in bolt = 4.68 / .0767 = 61 tons per sq.in.

Thus if the collar is stressed to 20 tons per sq.in. it is necessary to stress the bolt to 60 tons per sq.in. to cause movement. This would not be strictly correct as no account has been taken of the torsion of keeping the bolt from turning. However the collar stress could be put up still higher.

Perhaps you would try some experiments with these collars to see how much it takes to pull them off with an ordinary nut and spanner with different stresses in the collar (E).
  
  