Chart showing dissipation and pressure characteristics for oil cooling tube H (016).

Identifier  ExFiles\Box 149a\2\  scan0318
Date  23th August 1935
  
OIL COOLING
CHART N° CX.{Major Len W. Cox - Advertising Manager}107/1
DISSIPATION OF TUBE H (016)
22/3/4/19/18/4/231/43.3/7/8 N°30
OIL MEAN TEMP = 170°F
AIR INLET = 70°F
AIR VELOCITY = 1200FT/MIN (CONSTANT)
OIL FLOW (MOBILOIL A) = 20.5 LBS/MIN
INTERNAL WOUND (OPEN)
AIR VELOCITY IN FT./MIN.
500, 1000, 1500
DISSIPATION TO OIL FLOW
DISSIPATION TO AIR FLOW
PRESSURE V OIL FLOW
PRESSURE IN LBS/□ PER FT.
LBS/OIL/MIN/TUBE
B.T.U'S. PER HR. PER FT. RUN AT 100° T.D. AIR INLET TO MEAN OIL TEMP.