The voltage drop tests conducted on a car's head-lamp circuit.


Identifier  ExFiles\Box 167\1\  img186
Date  2nd October 1937
  
To By. {R.W. Bailey - Chief Engineer} from Rm {William Robotham - Chief Engineer} /RC. {R. Childs}
c. BY {R.W. Bailey - Chief Engineer} /RD.

6116.

Rm {William Robotham - Chief Engineer} /RC. {R. Childs} 3/MH. {M. Huckerby} 2.10.37.

VOLT DROP ON CAR HEAD-LAMP CIRCUIT.

In order to ascertain the voltage available on the shunt coil of the head-lamp dipping mechanism, for holding the reflector in the dipped position, tests of the volt drop on the headlamp circuit have been made.

The tests were carried out on chassis 26-G-VI which has fitted on it, the latest P.100/O.T. lamps.

Headlamp bulbs of 12 - 14V/60 watts and side and tail-lamp bulbs of 12-14V/6 watts were used.

Tests were taken with the switch in the H S & T position, thus including the effect of the side and tail lamps, and with the head lamps on 'normal' and 'dipped'. The results obtained were as follows -

Condition. Battery Terminal Volts. Lamp or Dipper Terminal Volts. Volt Drop.
Lamp "normal" 12.15 Lamp 11.10 1.05
Lamp "dipped" 12.20 ( Lamp 11.43 .77
( Dipper 11.77 .43

Rm {William Robotham - Chief Engineer} /RC. {R. Childs}
  
  