Rolls-Royce Archives
         « Prev  Box Series  Next »        

Data table for a Venturi Petrol Flow Meter using a CuSO4 gauge, correlating flow time with manometer readings.


Identifier  ExFiles\Box 37\2\  scan 133
Date  28th February 1918
  
H.H. 8.H. (500 T) (S.D. 408. 26-4-17.) Bm. 2/156/13.
X. 3180
28.2.18.

X. 3180 - VENTURI PETROL FLOW METER
(with CuSO4 gauge).

TABLE FOR G = .194 √H
OR P = 93.1√H
WHERE G = galls per min
AND P = pints per hour.

Time for 4 pints. Diff: of level
in manometer gauge (inches).

M. {Mr Moon / Mr Moore} S.
1 5 5.66
1 6 5.49
1 7 5.32
1 8 5.16
1 9 5.02
1 10 4.88
1 11 4.74
1 12 4.61
1 13 4.48
1 14 4.37
1 15 4.25
1 16 4.14
1 18 3.93
1 20 3.73
1 22 3.55
1 24 3.39
+ 1 26 3.23
1 28 3.09
1 30 2.95

Contd.
  
  
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).


Copyright Sustain 2026, All Rights Reserved.    whatever is rightly done, however humble, is noble
An unhandled error has occurred. Reload 🗙