Gaps and limits for setting a push button switch.

Identifier  ExFiles\Box 64\3\  scan0261
Date  20th November 1924
  
X8651
To RHC.{R. H. Coverley - Production Engineer} from EFC.
c. BY/RD.
EFC2/T20.11.24.

X.8651. PUSH BUTTON SWITCH.

We return to you EAC. push button switch B. The gaps and limits decided upon for this type of switch are as follows :-

Position. Carbone Gap. Copper Gap. Button depression.

Off. .063+12 -13 .090"+15 -15 0

Carbons in
contact. 0 .040"+5 -5 .029"+6 -6

Coppers in
contact. 0 0 .052"+9 -9

These figures will be useful for future reference in the setting of the switch.

On this particular switch, the carbon contacts need adjusting so as to meet earlier. It has also been noticed that one of the side stops comes into operation before the other, resulting in the lever tilting sideways slightly, after coming into contact with the earlier stop.

EFC.
  
  


Copyright Sustain 2025, All Rights Reserved.    whatever is rightly done, however humble, is noble