40/50 Oil Pump tests, with comparison data for a Feuerheerd pump.


Identifier  ExFiles\Box 149\2\  scan0015
Date  22th December 1927
  
40/50 OIL PUMP TESTS
FOR COMPARISON WITH FEUERHEERD PUMP

A {Mr Adams} / DELIVERY AT 100 R.P.M.
(Test at 22°C)

(Columns headed:) 40/50 FEUERHEERD
100 R.P.M AT 10 LB/□" PRESSURE, 1 GALLON IN 4 MIN 3 SECS. 4 MIN 50
40 LB/□" " - 4 MIN 4 1/2 SECS (text "4 1/2 SECS" is struck through) 4.71
60 LB/□" " - 4 MIN 6 SECS
100 LB/□" " - 4 " 6 "

B/ PUMP WILL JUST DELIVER AT 100 LB/□" PRESSURE AT
(Test at 9.5°C)
30 R.P.M

C/ PUMP WILL JUST LIFT MOTORINE "C" 3FT. 10 1/2 INS. (FLOOR LEVEL TO ¢ OF SUCTION PIPE) AT
50 R.P.M.

D {John DeLooze - Company Secretary} / (Test at 31°C)
1000 R.P.M - 100 LB/□" - 1 GALLON IN 27 3/5 SECS.
1.46

WT OF 40/50 PUMP 3LB 7 1/4 OZ

DELIVERY GOOD, ALSO PRESSURE IS STEADY UP TO 100 LB/□"
  
  