The low and high rate discharge tests of a faulty electrical cell.
| Identifier | ExFiles\Box 168b\3\ img285 | |
| Date | 3rd June 1930 guessed | |
| 2 JD {J. Draper - Frames} 85 On Low Rate Discharge only 42.2 ampere hours were obtained owing to the one cell being faulty this showing positive weakness. On High Rate Discharge Initial amperes = 10.7.9 Time to 104 " = 6.4 min " " 100 " = 9.7 " " " 90 " = 12.6 " " " 80 " = 18.5 " The same cell again showed faulty & showed positive weakness on the cadmium positive 1.5 negative .2. It will be interesting to open up this cell to find the cause of premature failure. G.J. | ||
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).