Mathematical analysis of auto switch shunt coil heating.

Identifier  ExFiles\Box 59\1\  Scan276
Date  21th February 1928
  
X4008
21.2.28.
AUTO SWITCH SHUNT COIL HEATING.

Suppose switch operates at shunt coil current C amperes (fixed for a given setting).

If the voltage is V and the resistance R ohms,

V = CR.{Mr Cra???ster / Mr Chichester}

The dissipation of the coil when the switch is just on the operating point is W₀ = C²R watts and is therefore proportional to R when R varies due to coil temperature variation.

Now R = Rₐ + β(t - tₐ)
where t is the coil temperature.
tₐ " " ambient "
R " " coil resistance.
and Rₐ " " coil resistance at the ambient temperature.

β being a coefficient of increase of resistance with temperature reckoned from the temperature tₐ.

Further by Newton's law of cooling the coil watts
W = γ(t - tₐ)
γ being another coefficient.

We have therefore
R = Rₐ + (β/γ)W

or W = (γ/β)R - (γ/β)Rₐ
  
  