Rolls-Royce Archives
         « Prev  Box Series  Next »        

Calculations for heat dissipation and critical temperature, comparing Mark VI and Mark V components.


Identifier  ExFiles\Box 149a\2\  scan0264
Date  6th November 1935
  
(APPENDIX - SHEET 3a)
Hs {Lord Ernest Hives - Chair} /Std.14/KW.6.11.35.

Using Mark VI 84 m.m. matrix and taking
ratio of Mark VI dissipation / Mark V dissipation = 1.15

(15% represents mean gain with Marston's latest Mark VI against Mark V).

Dissipation (for 2 sq.ft.)
= 62.2 x 1.15 = 71.5 B.T.U's/min/°C. temp.diff.

as before H / Δt = (602 x 71.5) / (144 x 2) = 149.4

Δt = H / 149.4 = 8100 / 149.4 = 54.3

Critical Temp. = 100 - 54.3 = 45.7°C.
  
  