Rolls-Royce Archives
         « Prev  Box Series  Next »        

Letter discussing the poor performance and failure of Young Accumulator Company batteries during testing.


Identifier  ExFiles\Box 164\4\  img112
Date  6th July 1933
  
Sg {Arthur F. Sidgreaves - MD} 4/E6.7.33

6th July 1933

My dear Campbell,

Many thanks for your letter of the 5th relative to the Young Accumulator Company and the testing of one of their batteries.

I find from our records that just about a year ago you raised this matter and, on taking it up with the Works, the information given was that tests of Young Accumulators do not show very good results and are considerably worse than the average result obtained from our standard Exide and Peto & Radford batteries.

The initial capacity tests were quite good and the units were put on/ test for use under actual running conditions.

After less than 12 months' service, however, both units failed due to the paste falling from the positive plates and being unable to settle on the bottom of the cell - therefore accumulating in the pockets forcing through the separators and so shorting the positive to the negative plates.

The separators were of a soft spongy nature and allowed the active material to become clogged in them.

We usually find that the battery people claim so much without being able to substantiate their performance claims over a long period, and as you know, a battery may give a very good initial performance, as this one did, but fail in its life tests.

We regularly get 5 and 6 years' life from our standard batteries whereas this battery only
  
  