Instructions and specifications for laying out a Bowdenex mechanism, including tables for conduits, cables, and abutments.
| Identifier | ExFiles\Box 120\2\ scan0027 | |
| Date | 12th June 1936 guessed | |
| HOW TO LAY OUT A Bowdenex MECHANISM. 1. Knowing the required working load choose a suitable cable and conduit from Table 1. 2. Decide on the run which the conduit will take:—The minimum mean radius of curvature should be approximately 15 x D where “D” is conduit overall diameter in inches. The cable should always leave the bore of the abutment lying truly along its axial centre, at a point midway between the lowest and highest points of the arc of travel of the lever it joins. 3. Wherever practicable make all cables and conduits of equal length when they are operated simultaneously by one means of operation, as in bogie braking on rail cars or six wheeled vehicles. This is equally important in four wheel brake systems where any wide variation in front and rear cable lengths should be avoided by using rods to bridge the intervening space. 4. Choose suitable abutments, plain or tapered, from Table 2. Consider how you can arrange brackets to receive them. Where plain or flatted screwed ends are used they can be threaded into position through the brackets but in all cases the brackets must be slotted to clear the inner cable and enable the whole assembly to be mounted in position. Plain abutments must either be a light driving fit or clamped in their locating brackets. Tapered only require a registering tapered hole in the bracket. 5. Adjustment should be provided for on the cable by the use of screwed end pieces. A wide range of these is available as listed in Table 3. Do not create a special non-standard size if you can possibly avoid it as this increases cost unless very large quantities are required. 6. Select from Tables 3, 4 and 5 suitable end pieces and forks. Determine the finished lengths making due allowance for sufficient clearance between end pieces and abutments to provide the full range of adjustment. The dimensions L2—L1 Table 3 and L3 Table 4 must be maintained as they are essential to sound swaging of the end pieces to their cables. If one end of the conduit be fixed and the other moves, make sure that under no operating condition is the conduit pulled taut or beyond the minimum radius in para. 2 above. 7. We strongly advise that lubricators be fitted at the centre of all conduits. A graphited lubricant is essential and we recommend “Gredag” as supplied by Messrs. E. {Mr Elliott - Chief Engineer} G. {Mr Griffiths - Chief Accountant / Mr Gnapp} Acheson Ltd., 40, Wood Street, London, S.W.1. 8. We earnestly request designers to enlist our co-operation which is freely and gladly given. Our experience frequently enables us to improve the efficiency and to reduce the cost of new designs. The use of our standard fittings cuts costs:—Do not conclude we have no fitting if it is not on this sheet—Ask us, we have many more not included in the tables here published. TABLE 1. STANDARD CONDUITS AND CABLES MAX LOADS LBS | CONDUITS (No., DIA. O {Mr Oldham} /A, WEIGHT LBS/FT) | CABLES (No., DIA. O {Mr Oldham} /A, WEIGHT LBS/FT, BREAKING STRAIN LBS) 75 | T2AH, .260", .107 | 19/2A, .087", .015, 650 100 | T2AH, .260", .107 | 36/3, .111", .021, 1400 150 | T3*, .234", .083 | 36/3, .111", .021, 1400 200 | T3H*, .272", .122 | 36/3, .111", .021, 1400 250 | T3H*, .272", .122 | 36/4, .129", .032, 1800 300 | T4, .319", .173 | 36/4, .129", .032, 1800 350 | T5, .385", .242 | 36/5, .162", .052, 2000 450 | T5, .385", .242 | 36/6, .192", .075, 3600 600 | T6, .441", .320 | 36/6, .192", .075, 3600 700 | T6A, .483", .359 | 36/6B, .220", .095, 4300 800 | T6H, .507", .437 | 36/6B, .220", .095, 4300 1500 | T7, .584", .562 | 36/7, .255", .128, 6500 2200 | T7/T10, .862", 1.468 | 36/7, .255", .128, 6500 CONDUITS MARKED * CAN BE SUPPLIED COVERED BLACK W.P. METRIC CONVERSION CONSTANTS LBS x .4535 = KILOS, INCHES x 25.399 = MMS., LBS/FT x 1.488 = KILOS PER METRE TABLE 2. ABUTMENTS CONDUIT NO. | PLAIN (L, l, D, d) | TAPERED θ=5° (L, l, D, d) T2AH | 1", 5/8", 3/8", 11/64" | 1", 5/8", 3/8", 11/64" T3 | 1", 5/8", 3/8", 11/64" | 1", 5/8", 3/8", 11/64" T3H | 1", 5/8", 3/8", 11/64" | 1", 5/8", 3/8", 11/64" T4 | 1 1/4", 7/8", 7/16", 13/64" | 1 1/4", 7/8", 7/16", 13/64" T5 | 1 5/8", 1", 1/2", 17/64" | 1 5/8", 1", 1/2", 13/32" T6 | 1 7/8", 1 1/4", 9/16", 21/64" | 1 7/8", 1 1/4", 9/16", 21/64" T6A | 2 1/4", 1 5/8", 5/8", 25/64" | 2 1/4", 1 5/8", 5/8", 1" T6H | 2 1/4", 1 5/8", 5/8", 25/64" | 2 1/4", 1 5/8", 5/8", 2" T7 | 2 7/8", 2", 3/4", 29/64" | 2 7/8", 2", 3/4", 29/64" T7/T10 | 4", 2 3/4", 1", 29/64" | 4", 2 3/4", 1", 29/64" THESE ABUTMENTS FIT THE CONDUITS OPPOSITE WHICH THEY ARE SHOWN. PLAIN MUST BE CLAMPED AT d OR THEY CAN BE SCREWED GAS THREAD. TAPERED FORM THE BEST ASSEMBLY. TABLE 3. PLAIN END OR HEX END / FLATTED OR HEX END SCREWED DIA D | SWAGE DIA D | SHORT (PLAIN L1, PLAIN L2, FLATORHEX L2) | LONG (PLAIN L1, PLAIN L2, FLATORHEX L2) | TO SUIT INNER CABLES 1/4 B.S.F | .292" | 1", 2 3/8", 3 1/8" | 1 3/8", 4 1/8", 4 7/8" | 19/2A 36/3 36/4 1/4 B.S.F | .365" | 1", 2 3/8", 3 1/8" | 1 3/8", 4 1/8", 4 7/8" | 36/5 5/16 B.S.F | .365" | 1 1/8", 2 7/8", 3 3/4" | 1 3/8", 4 1/4", 5" | 36/4 36/5 36/6 36/6B 3/8 B.S.F | .365" | 1 1/4", 3 1/4", 4 1/8" | 1 3/4", 4 3/4", 5 5/8" | 36/6 36/6B 3/8 B.S.F | .493" | 1 1/4", 3 1/4", 4 1/8" | 1 3/4", 4 3/4", 5 5/8" | 36/7 7/16 B.S.F | .493" | 1 3/8", 3 5/8", 4 1/2" | 1 7/8", 5", 5 7/8" | 36/7 & UP 1/2 B.S.F | .493" | 1 1/2", 4", 4 7/8" | 2", 5 1/2", 6 3/8" | 36/7 & UP FLATTED ENDS HAVE FLATS PRESSED ON THEM IN LIEU OF A HEXAGON TO RECEIVE A SPANNER. THEY ARE LESS EXPENSIVE THAN HEXAGONAL, ARE EQUALLY EFFECTIVE, AND ARE STRONGLY RECOMMENDED. SPECIAL STEELS ARE NECESSARY TO ENSURE SOUND SWAGING AND WE CANNOT GUARANTEE SATISFACTION UNLESS END PIECES ARE MADE IN OUR WORKS. | ||
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).