Gauge of contact point arms for a contact breaker test.
| Identifier | ExFiles\Box 35\6\ scan 358 | |
| Date | 10th November 1927 | |
| To RHC. {R. H. Coverley - Production Engineer} from EFC. {E. Fowler Clarke - Electrical Engineer} X8692 EFC {E. Fowler Clarke - Electrical Engineer} 5/T10.11.27. CONTACT BREAKER TO LEC.2460. Further to our EFC {E. Fowler Clarke - Electrical Engineer} 7/T7.11.27, will you kindly note that the gauge of the contact point arms should be .064", similar to the one which you made up for us to test. We have noted, however, that there is another gauge specified as an alternative, viz. .080", and we are handing you herewith the contact breaker which ran on the test, so that you can re-arrange this for further test with .080" contact point arm, which we should like to have as soon as possible. EFC. {E. Fowler Clarke - Electrical Engineer} | ||
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).