Faulty Watsons Dynamo (No. 128) from Chassis 61-H-5 with suggested repairs.
| Identifier | ExFiles\Box 47\4\ Scan195 | |
| Date | 10th July 1924 | |
| X4383 EFC. {E. Fowler Clarke - Electrical Engineer} BY4/H. 10. 7. 24. CHASSIS 61-H-5. WATSONS. DYNAMO NO. 128. The Test Dept. have returned us the above dynamo, which we would like you to collect from our Department, in connection with which they report as follows:- "We have now examined and tested the above and find it faulty. We find that the solder has run from the Commutator bar connections due to excessive heating up of the armature. Perhaps due to running on charge with an open circuit. The machine appears to have had a good deal of running and the commutator is roughed up but appears to have been fairly free from arcing of brushes". I would suggest that you solder up the commutator bar connections so as to make these good, but without any further work being done, might try the dynamo under full load, to check whether the temperature rise is then sufficient to account for the trouble due to faulty brush bedding combined with the wrong angular position of the control brush. BY. {R.W. Bailey - Chief Engineer} | ||