Comparative analysis with a graph showing temperature increase over time for three different 'hot spot' systems.

Identifier  ExFiles\Box 66\2\  scan0152
Date  2nd February 1926 guessed
  
contd :-
-7-
COMPARATIVE CURVES FOR 3 SYSTEMS.
AVERAGE TEMP RELATIVE TO STARTING TEMP
STD HOT SPOT BUTTERFLY VALVE IN EXH. PIPE SHUT
SUPERHEAT HOT SPOT
SIMPLE WATER HEATED HOT SPOT
TIME FROM START (MINS)
i.e., exhaust gas for the standard system, steam for the superheated and water for the simple water system - increase when starting from cold. By average temperature is meant the mean of the inlet and outlet temperatures of the hot spot.
The exhaust temperatures were taken with thermo couples. Although the rate of heat to the charge at any instant is approximate proportional to the temperature difference on each side of the hot spot, there will be a considerably greater temperature drop between the hot exhaust gas and the walls of the hot spot than between the water and the hot spot. Examining these curves without remembering this fact would lead us to suppose that the standard system was considerably superior contd:-
  
  