Instructions for a temperature and voltage leakage test on a coil-case, comparing Stabalite and Redmanol materials.


Identifier  ExFiles\Box 45\4\  Scan304
Date  29th June 1920
  
ROLLS-ROYCE LTD.
INSTRUCTIONS.

To__________________________________
Order No.____________________________ Customer's No. S

a coil-case in the oven, and. starting from about 30°c, applying increasing voltages for the leakage readings at each stage of 30°c temperature rise, up to 100°C.

It will be seen that the Stabalite is practically leakless right up to 100°c., whereas the Redmanol always leaks well before this temperature is reached. The Stabalite case was found to be slightly soft immediately on removing from the oven at 100°c. In the table following, the readings for the maximum RMS voltage of 2,420 which was applied in each case are given.

Signed ______________________________ (contd)
This Sheet must be filed on completion of the work.