Investigation into a faulty Goshawk Dynamo from chassis 56/S/3 for Col. Heywood, detailing repairs and further recommendations.


Identifier  ExFiles\Box 47\4\  Scan134
Date  22th October 1923
  
To EX. from EFC. {E. Fowler Clarke - Electrical Engineer}
c. EP. {G. Eric Platford - Chief Quality Engineer}

X4383
EFC {E. Fowler Clarke - Electrical Engineer} 2/T22.10.23.

X.4383 - GOSHAWK(Aero Engine)(Codename for 20HP Car / Aero Engine after Kestrel(Aero Engine)) DYNAMO. - CHASSIS 56/S/3.
COL. HEYWOOD.

We have made the requested investigation of dynamo No.166. It was first found that the melting of the solder from the commutator connections had destroyed the continuity of the armature winding. This was corrected by having the commutator connections re-soldered and the armature was replaced without, however, having done anything whatever to the brushes.

It was then run under normal conditions and the current output was found to be quite normal, just as if it were set to our present production test. So far as we could ascertain there did not appear to be any reason why the condition or position of the brushes should have caused the machine to melt the commutator solder.

Before returning the machine to the customer some improvement in the brush bedding could be effected, and there are a number of minor faults which would be corrected if the instructions contained in our Specification of Readjustment of Faulty Dynamos dated 25.7.23, were carried out on this machine.

Will you kindly let us know whether we should do this work in this Dept. or send the machine to Mr. Brock to have the work carried out to your instructions ?

EFC. {E. Fowler Clarke - Electrical Engineer}
  
  