Standardization of oil pumps for Bentley crankshafts and big end bearings to address noise issues.


Identifier  ExFiles\Box 115\1\  scan0227
Date  21th December 1936
  
1620

E. {Mr Elliott - Chief Engineer} from Rm. {William Robotham - Chief Engineer}
c. to Hs. {Lord Ernest Hives - Chair}
c. to Sg. {Arthur F. Sidgreaves - MD}
c. to By. {R.W. Bailey - Chief Engineer}

Rm {William Robotham - Chief Engineer} 5/R.21.12.36.

BENTLEY CRANKSHAFT & BIG END BEARINGS.

With reference to E.4/HP.18.12.36., the larger oil pump was standardised with 22° Helix angle gears, because this size of pump with straight teeth was noisy; furthermore, apart from our own 15,000 mile test, six of these pumps have been running on customers' cars in conjunction with lead bronze bearings on the Continent, and no trouble whatever has been experienced. Owing to noise, the P.III oil pump has been standardised with the same Helix angle gears.

It will be remembered that we were in serious production trouble with noise on P.II oil pumps not long before these went out of production, and we want to avoid a similar epidemic in the future. Research is being undertaken to see why a greater oil delivery causes noise.

With regard to the two pressure relief valve scheme, this was tested on 6.B.IV. At the moment, in our experience, the additional complication is not justified, particularly in view of the fact that with the larger oil pump the speed is lower at which the oil starts to pass the main relief valve to the timing gears.

Rm. {William Robotham - Chief Engineer}
  
  