Test results and calculations for auxiliary and chassis condensers.

Identifier  ExFiles\Box 34\1\  Scan116
Date  7th October 1919
  
X.2512 - RE CONDENSERS.

(1) The three auxiliary condensers on resonance together give a reading of 3.5 on Lucas volt meter.

(2) The same on 350 volts from transformer together give a reading of 3.8. Hence resonance voltage = 320.

(3) The three auxiliaries plus a chassis condenser give a reading of 9.5 on resonance, and a reading of 7.0 on 350 volts. Hence resonance voltage = 475

Ratio of total capacities
= (9.5 / 3.5) x (320 / 475)
= 7.0 / 3.8 = 1.8

(4) The three auxiliary condensers on 400 volts give a reading of 4.5 on Lucas voltmeter., and 8.0 on adding one chassis condenser. Ratio 1.8

(5) On 450 volts readings are 5.5 and 9.6.
Ratio 1.75
  
  