Experimental use and failure of a battery, deeming it unsuitable for its purpose.
| Identifier | ExFiles\Box 48\3\ Scan334 | |
| Date | 28th August 1923 guessed | |
| contd:- -2- Apart from these periods it was subject to ordinary experimental use from 5.11.23 to 11.2.24, when it was found that No.5 cell had failed by shorting internally. It will be seen from the above that this type of battery is entirely unsuitable for our purpose. It is a battery which is no doubt capable of giving big ampere hour capacity provided the rate of discharge is kept low. This is not at all suitable for our requirements but it is not to be understood from this that we require the other extreme but rather a suitable happy medium. It was not possible, on this battery, to take temperatures and densities of electrolyte because the conn-ecting bars passed underneath the filler holes. MADE BY CROXLEY ----------------- | ||