Report page with a graph comparing the increase of induction pipe temperatures for superheated, standard exhaust heated, and water-heated systems.

Identifier  WestWitteringFiles\O\2January1926-March1926\  Scan86
Date  12th February 1926 guessed
  
contd :-

-6-

[Graph Title] INCREASE OF INDUCTION PIPE TEMPERATURES AFTER STARTING FROM COLD.
[Graph Y-Axis] TEMP oC
[Graph X-Axis] TIME FROM START
[Graph Labels] SUPERHEATED, STD EXH HEATED, AIR TEMP, WATERHEATED

These curves were selected from a number of tests so that the outside air temperature was as near as possible the same for each experiment. It will be seen that the standard exhaust system and the superheated system are little different with regard to temperature rise but both lie above the water heated system.

It cannot be claimed that the above curves give a strict comparison of the three systems for reasons put forward earlier in this report, but as the same fuel was employed for all these tests we are able to see that there is no marked difference between the superheated and standard systems and that both of these show an advantage over the simple water heated system.

TEMPERATURE RISE OF THE HEATING MEDIUM IN THE HOT SPOT.

The following curves show the av average temperatures of the heating medium :-

contd :-
  
  