Test results for terminal potential difference of standard Exide batteries for 20HP and 40/50HP models.


Identifier  ExFiles\Box 54\2\  Scan168
Date  11th January 1926
  
RR 300 (20 Bks.) (SK 354 5-12-22 MP 264049
X4617 E
108714
ROLLS-ROYCE LIMITED.
INSTRUCTIONS.
To: E.T.G.
Order No.:
Customer's No.:
Date: 11 - 1 - 1926
Re: J.B.17.D.
Terminal PDs of Standard Exide Batteries
The terminal PDs of Standard 20HP & 40/50HP Exide Batteries were observed when charging at 9 & 12 amperes respectively. The results are tabulated below.

| Amperes | 20HP | 40/50HP |
|---------|----------------|-----------------|
| | cell no | 6XL3/4/1 | cell no | 6RR5/1/3 |
| 9.0 | -1 | 2.71 | -1 | 2.69 |
| | 2 | 2.71 | 2 | 2.70 |
| | 3 | 2.68 | 3 | 2.69 |
| | 4 | 2.68 | 4 | 2.69 |
| | 5 | 2.68 | 5 | 2.70 |
| | +6 | 2.68 | +6 | 2.70 |
| 12.0 | -1 | 2.76 | -1 | 2.71 |
| | 2 | 2.76 | 2 | 2.72 |
| | 3 | 2.70 | 3 | 2.71 |
| | 4 | 2.70 | 4 | 2.71 |
| | 5 | 2.70 | 5 | 2.72 |
| | +6 | 2.70 | +6 | 2.72 |

More results wanted.
Signed: G.J.
This Sheet must be filed on completion of the work.
  
  